Product Information
Used to determine the
inhalation and exhalation resistance of a mask under specified conditions.
Standards
GB / T 32610-2016, GB
2626
Instrument characteristics
1. Touch screen control,
English menu, man-machine dialogue mode, easy operation.
2. Built-in thermal
printer, it is convenient to quickly print test results on site.
3. Two modes of breath
detection and inhalation detection can be set.
4. The automatic switching
device of the respirator pipeline solves the problem that the tester pulls out
the pipe and accidentally connects the pipeline when testing.
5. 3D printed standard
head mold, which simulates the actual inhalation and exhalation of the human
body, improving the accuracy of the data.
Technical Parameters
Flowmeter range |
0 ~ 100L / min, accuracy is 3% |
Digital differential pressure measurement range |
0 ~ 1000Pa, accuracy is 1Pa |
Pumping capacity of air pump |
≥100L / min |
Printer |
Mini thermal printing |
Power supply |
AC220V 50HZ 650W |
Dimensions |
680 × 600 × 1000mm |
Weight |
50kg |